Development and manufacture of engine control modules
sales@gencontrol.co.uk
keeping it simple...
Contactor image
Description
Top mount auxiliary contact block.
Suitable for NC1 and NC2 contactors.
Description
Mechanical Interlock for NC1 and NC2 Contactors
Description
Contactor 4 Pole 9A / 4kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 4KW / 9 Amp AC3 and 20 Amp AC1.
With 230V 50hz Coil.
NC10904-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
NC1M0932 is suitable for NC1-09, NC1-12, NC1-18, NC1-25 and NC1-32 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter configerations.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 12A / 5.5kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 5.5KW / 12 Amp AC3 and 20 Amp AC1.
With 230V 50hz Coil.
NC11204-240V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
NC1M0932 is suitable for NC1-09, NC1-12, NC1-18, NC1-25 and NC1-32 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter configerations.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 25A / 11kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 11KW / 25 Amp AC3 and 40 Amp AC1.
With 230V 50hz Coil.
NC12504-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
NC1M0932 is suitable for NC1-09, NC1-12, NC1-18, NC1-25 and NC1-32 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter configerations.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 40A / 18.5kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 18.5KW / 40 Amp AC3 and 60 Amp AC1.
With 230V 50hz Coil.
NC14004-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC1-40 to NC1-65

NC1M4065 is suitable for NC1-40, NC1-50 and NC1-65 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 50A / 22kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 22KW / 50 Amp AC3 and 80 Amp AC1.
With 230V 50hz Coil.
NC15004-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC1-40 to NC1-65

NC1M4065 is suitable for NC1-40, NC1-50 and NC1-65 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 65A / 30kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 30KW / 65 Amp AC3 and 80 Amp AC1.
With 230V 50hz Coil.
NC16504-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC1-40 to NC1-65

NC1M4065 is suitable for NC1-40, NC1-50 and NC1-65 contactors.
Suitable for 3 pole and 4 pole contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 80A / 37kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 37KW / 80 Amp AC3 and 110 Amp AC1.
With 230V 50hz Coil.
NC18004-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC1-80 to NC1-95 4 Pole Only

NC1M8095 is suitable for NC1-80 and NC1-95 4 pole contactors.
Suitable for 4 pole contactors only.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 4 Pole 95A / 45kw 4 Main N/O Poles 230v AC

4 Pole Contactor with 4 main normally open poles.
Rated at 45KW / 95 Amp AC3 and 110 Amp AC1.
With 230V 50hz Coil.
NC19504-230V
For 4 pole load switching.
Din rail mountable.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC, 415v AC or 24v DC coils.
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC1-80 to NC1-95 4 Pole Only

NC1M8095 is suitable for NC1-80 and NC1-95 4 pole contactors.
Suitable for 4 pole contactors only.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 115Amp / 55KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 55KW / 115 Amp AC3 or 200 Amp AC1.
NC211504-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-115 to NC2-150

NC2IL01 is suitable for NC2-115 and NC2-150 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 150Amp / 75KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 75KW / 150 Amp AC3 or 200 Amp AC1.
NC215004-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-115 to NC2-150

NC2IL01 is suitable for NC2-115 and NC2-150 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 185Amp / 90KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 90KW / 185 Amp AC3 or 275 Amp AC1.
NC218504-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-185 to NC2-225

NC2IL02 is suitable for NC2-115 and NC2-150 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 225Amp / 110KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 110KW / 225 Amp AC3 or 275 Amp AC1.
NC222504-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-185 to NC2-225

NC2IL02 is suitable for NC2-115 and NC2-150 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 265Amp / 132KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 132KW / 265 Amp AC3 or 315 Amp AC1.
NC226504-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-265 to NC2-500

NC2IL03 is suitable for NC2-265, NC2-330, NC2-400 and NC2-500 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 330Amp / 160KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 160KW / 330 Amp AC3 or 380 Amp AC1.
NC233004-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-265 to NC2-500

NC2IL03 is suitable for NC2-265, NC2-330, NC2-400 and NC2-500 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 400Amp / 200KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 200KW / 400 Amp AC3 or 450 Amp AC1.
NC240004-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-265 to NC2-500

NC2IL03 is suitable for NC2-265, NC2-330, NC2-400 and NC2-500 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.
Contactor 630Amp / 250KW 4 Pole 230v AC Coil

NC2 Contactor with 4 main normally open poles but no auxiliary contacts.
Rated at 250KW / 630 Amp AC3 or 800 Amp AC1.
NC263004-230V AC
Each NC2 Contactor comes fitted with a metal base plate for secure mounting.
Budget priced alternative to Siemens, Telemecanique, Moeller etc.
Available with 24v AC, 48v AC, 110v AC, 230v AC or 415v 50/60hz AC coils
Coil tolerance of + / - 10% so 415V is also suitable for 400V and 440V
VDE approved to EN60947 for Europe.
UL Approved for North America.
Top mount auxiliary contact block.
One normally open and one normally closed contacts.
Suitable for NC1 and NC2 contactors.
Mechanical Interlock for Contactors NC2-630

NC2IL04 is suitable for NC2-630 contactors.
Used to mechanically interlock 2 contactors together.
Used in reversing starter and star delta starter applications.
Physically prevents both contactors from energising at the same time.
Side mounts inbetween 2 contactors.

4 Pole contactors are suitable for a single and 3 phase + neutral ATS control panels. Please email us to get a quote. Worldwide shipment is available.
Delivery within UK is normally free of charge.