AECM105-IP67-Diesel

Auto start modules

Model: AECM105

User Manual

The Model AECM105 is a new generation of AECM designed to automatically / remotely and manually start and stop the engine either by using wired remote start input (so called 2 wire start) or via optional devices: 24/7 digital timer, wireless key fob(s) or/and Battery Voltage Sensor. The wireless key fob control allows to start and stop the engine remotely within approximately 100 m distance (1000 m distance is optional). The actual working distance depends on many factors and could be much less than 100 m for instance if the key fob is used inside the building. The Battery Voltage Sensor (BVS) controls the engine starting battery voltage (or external battery bank) and able to start the engine automatically upon registering Low Voltage Threshold 11.8Vdc (23.6V) This LVT can be re-adjusted by customer on-site. It will continue to run the engine until the engine starting battery becomes fully charged at 13.8Vdc (27.6V).The BVS will then register High Voltage Threshold and shut down the engine. This HVT can be also re-adjusted by customer on-site.
AECM105 will indicate the operational status and fault conditions, automatically shut down the engine and indicate the start engine failure by flashing "START FAIL" LED on the front panel. Other faults are indicated by steady LED. Remote wired operation of the module is via single pole normally open maintained switch connected between terminal #5 (wire 1) and battery negative terminal #13 (wire GR/Y). The switch is shown on wiring diagram as "RST".. Read more...

Key Features

  • IP67 rated enclosure

  • Remote / Local start and stop

  • Low oil pressure shut down

  • High engine temperature shut down

  • Manual / Remote shutdown by pressing emergency stop push button

  • Over speed shut down

  • Under speed shut down

  • Self-regulated duration of each attempt

  • Automatic pre-heat before start via glow plug (optional, please consider using table "A" shown below)

  • Automatic load control (optional, please consider using table "A" shown below)

  • Can be programmed to work with normally open fuel solenoid (energize-to-stop type)

  • Wireless start / stop (optional, please consider using table "A" shown below)

  • Very low power consumption in stand-by mode (10mA max)

  • All parameters are user configurable (prior to order)

Table A

Optional Features/Items

Item

Price

GBP

Wireless Key fob
(100, 1000, 3000m options available during checkout)

(no battery fitted)

From 22.00

BVS sensor
Able to control an external battery bank voltage as well as the generator starting battery voltage. Runs the generator automatically when the controlled battery voltage drops below the set limit.
2 core glanded cable attached to terminals 19(+) and 20(-) if ordered below:

39.00

2 Core Cable for BVS sensor

3.00 (per M)
Note: Please select the number of metres during checkout (use "Quantity" field)

BVS Sensor
(for engine starting battery voltage control only), runs the generator automatically when the starting battery voltage drops below the set limit)

29.00

Output for a glow plug (pre-heat)

12.00

Load Control output

12.00

Settings for N/O fuel solenoid valve
(with mechanically driven fuel pump)

42.00

24/7 Digital timeswitch fitted

24.00

Panel mounted
emergency stop button switch

10.00

12V 1A Lead acid trickle charger

10.00

multi-core cable fitted and glanded

3.00 (per M)
Note: Please select the number of metres during checkout (use "Quantity" field)

40A 12V or 24V fuel/starter/pre-heat/
load/ control
external power relays.

From 3.00 (each)